 Bulletin I27402 rev. B 09/06
IRKD600.. SERIES
STANDARD DIODES Features
High current capability 3000 VRMS isolating voltage with non-toxic substrate High surge capability High voltage ratings up to 2000V Industrial standard package UL E78996 approved RoHS Compliant
SUPER MAGN-A-pakTM Power Modules
600 A
Typical Applications
Rectifying bridge for large motor drives Rectifying bridge for large UPS
Major Ratings and Characteristics
Parameters
IF(AV) @ TC IF(RMS) @ TC IFSM I2t @ 50Hz @ 60Hz @ 50Hz @ 60Hz I2t VRRM TSTG TJ range range range
IRKD600..
600 100 942 100 19.0 20.1 1805 1683 18050 800 to 2000 - 40 to 150 - 40 to 150
Units
A C A C KA KA KA2s KA2s KA2s V C C
www.irf.com
1
IRKD600.. Series
Bulletin I27402 rev. B 09/06
ELECTRICAL SPECIFICATIONS Voltage Ratings
Type number Voltage Code
08 IRKD600.. 12 16 20
VRRM , maximum repetitive peak reverse voltage V
800 1200 1600 2000
VRSM , maximum nonrepetitive peak rev. voltage V
900 1300 1700 2100
IRRM max.
@ TJ max.
mA
50
Forward Conduction
Parameter
I F(AV) Maximum average forward current @ Case temperature I F(RMS) Maximum RMS forward current I FSM Maximum peak, one-cycle forward, non-repetitive surge current
IRKD600..
600 100 942 19.0 20.1 16.2 17.2
Units Conditions
A C A KA 180 conduction, half sine wave @ TC = 100C t = 10ms t = 8.3ms t = 10ms t = 8.3ms KA2s t = 10ms t = 8.3ms t = 10ms t = 8.3ms
2
180 conduction, half sine wave
No voltage reapplied 100% VRRM reapplied No voltage reapplied 100% VRRM reapplied Sinusoidal half wave, Initial TJ = TJ max.
I2t
Maximum I2t for fusing
1805 1683 1319 1230
I t
2
Maximum I t for fusing
2
18050 0.70 0.77 0.28 0.25 1.24
KA s t = 0.1 to 10ms, no voltage reapplied V (16.7% x x IF(AV) < I < x IF(AV)), TJ = TJ max. (I > x IF(AV)), TJ = TJ max. m (16.7% x x IF(AV) < I < x IF(AV)), TJ = TJ max. (I > x IF(AV)), TJ = TJ max. V Ipk = 1800A, TJ = 25C, tp = 10ms sine pulse
VF(TO)1 Low level value of threshold voltage VF(TO)2 High level value of threshold voltage r f1 r f2 VFM Low level value of forward slope resistance High level value of forward slope resistance Maximum forward voltage drop
Blocking
Parameter
V INS I RRM RMS isolation voltage Maximum peak reverse and off-state leakage current
IRKD600..
3000 50
Units Conditions
V mA t=1s TJ = TJ max., rated VRRM applied
2
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. B 09/06
Thermal and Mechanical Specifications
Parameter
TJ Tstg R thJC Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case R thC-hs Max. thermal resistance, case to heatsink T Mounting torque 10%SMAP to heatsink busbar to SMAP wt Approximate weight Case style 6-8 12 - 15 1500 g Nm
A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound
IRKD600..
- 40 to 150 - 40 to 150 0.065
Units Conditions
C
K/W
Per junction, DC operation
0.02
K/W
SUPER MAGN-A-pak
See outline table
RthJC Conduction
(The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC)
Conduction angle
180 120
Sinusoidal conduction
0.009 0.011 90 60
Rectangular conduction
0.006 0.011 0.014 0.021 30
Units
Conditions
0.015 0.022 0.037
K/W
TJ = TJ max.
0.038
Ordering Information Table
1
Device Code
~
IRK
1 1 2 3 4 Module type
D
2
600
3
-
20
4
+ 2
Circuit configuration D = 2 diodes in series Current rating Voltage code: Code x 100 = VRRM (See Voltage Ratings Table)
3
www.irf.com
3
IRKD600.. Series
Bulletin I27402 rev. B 09/06
Outline Table
All dimensions in millimeters (inches)
Ma ximum Allowable Cas T e emperature (C)
140 130 120 110 100
IRKD600.. S eries R thJC (DC) = 0.065 K/ W
Maximum Allowab le Ca s T e emperature (C)
150
150 140 130 120 110 100 30 90 80 0 200 400 600 800 1000 Average Forward Current (A) 60 90 120 180 DC
Conduction Period
IRKD600.. S eries R thJC (DC) = 0.065 K/ W
Conduction Angle
30 90 80 0 100 200 300
60
90 120 180
400
500
600
700
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
4
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. B 09/06
700 600 500 400 300 200 100 0 0 100 200 300 400 500 600 Average Forward Current (A)
Conduction Angle
Maximum Average Forward Power Loss (W)
Maximum Average Forward Power Loss (W)
1000 900 800 700 600 500 400 300 200 100 0 0 200 400 600 800 1000 Average Forward Current (A) IRKD600.. S eries Per Junction TJ= 150C R MS Limit
Conduction Period
180 120 90 60 30 RMS Limit
DC 180 120 90 60 30
IRKD600.. S eries Per Junction T = 150C J
Fig. 3 - Forward Power Loss Characteristics
Peak Half S Wave Forward Current (A) ine 18000
Fig. 4 - Forward Power Loss Characteristics
20000 18000 16000 14000 12000 10000 8000 6000 4000 0.01 IR KD600.. S eries Per Junction 0.1 Pulse Train Duration (s) 1
Peak Half S Wave Forward Current (A) ine
At Any R ated Load Condition And With R ated VRRM Applied Following S urge. 16000 Initial T = 150C J @60 Hz 0.0083 s 14000 @50 Hz 0.0100 s 12000 10000 8000 6000 4000 1 10 100
Numb er Of Equa l Amplitude Half Cyc le Current Pulses (N)
Maximum Non Repetitive S urge Current Versus Pulse T rain Dura tion. Initial T = 150C J No Voltage Reapplied Rated VRRM Rea pplied
IRKD600.. S eries Per Junc tion
Fig. 5 - Maximum Non-Repetitive Surge Current
1000
Fig. 6 - Maximum Non-Repetitive Surge Current
Maximum T otal F orward Power Loss (W)
R th
04 0.
DC 800
600
180 (S ine)
K/ W 0. 12 K/ W 0.1 6K /W
0. 08
400 IR KD600.. S eries Per Junc tion T = 150C J 0 200 400 600 800
200
0.2 5K /W 0.3 5K /W 0.5 K /W
06 0.
A S
W K/
W K/
= 2 0.0 W K/ ta el -D R
0
1000 0
25
50
75
100
125
150
T otal R MSOutput Current (A)
Maximum Allowable Ambient T emperature (C)
Fig. 7 - Forward Power Loss Characteristics
www.irf.com
5
IRKD600.. Series
Bulletin I27402 rev. B 09/06
3000
R th
02 0.
Maximum T otal Power Loss (W)
2500 2000 1500 1000 500 0 0 200 400
180 (S ine) 180 (R t) ec
K/ W 0. 04 K/ W 0.0 5K /W
0. 03
A S
W K/
= /W 1K 0.0 ta el -D
0.0 8K /W
0.12 K/ W
R
2 x IR KD600.. S eries S ingle Phase Bridge Connected TJ = 150C 600 800 1000
0.2 K /
W
1200 0
25
50
75
100
125
150
T otal Output Current (A)
Maximum Allowable Ambient T emperature (C)
Fig. 8 - Forward Power Loss Characteristics
4500
R th
Maximum T otal Power Loss (W)
4000 3500 3000 2500 2000 1500 1000 500 0 0 300 600 900 1200 1500 0 1800 3 x IRKD600.. S eries T hree Phase Bridge Connected T J = 150C 120 (Rec t)
0. 02
K/ W 0.0 3K /W
0.0 5K /W
A S
= 01 0. W K/ ta el -D R
W 0.12 K /W 0.2 K/ W
0.08 K/
25
50
75
100
125
150
T otal Output Current (A)
Maximum Allowable Ambient T emperature (C)
Fig. 9 - Forward Power Loss Characteristics
10000 Ins tantaneous Forward Current (A)
0.1 IRKD600.. S eries Per Junc tion
1000 TJ= 25C TJ= 150C
T ransient T hermal Impedance ZthJC (K/ W)
0.01
S teady S tate Value: RthJC = 0.065 K/ W (DC Operation) 0.001 0.001 0.01 0.1 1 10 100
IRKD600.. S eries Per Junction 100 0.5 1 1.5 2 2.5 3 3.5
Instantaneous Forward Voltage (V)
S quare Wave Puls Duration (s) e
Fig. 10 - Forward Voltage Drop Characteristics
Fig. 11 - Thermal Impedance ZthJC Characteristic
6
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. B 09/06
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 09/06
www.irf.com
7


▲Up To Search▲   

 
Price & Availability of IRKD60006

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X